Nokia radio category illustration
Illustration
Nokia

FRIG

What it does: Converts and amplifies radio signals. Operating RF bands / ranges: 1700 / 2100 MHz.

1 part number: 472704A

Viewing: model overview

Request a Quote

Request current availability, condition and pricing. Delivery terms are agreed in the quotation.

Main specifications

TechnologiesFDD-LTE
Operating RF bands / ranges1700 / 2100 MHz
Uplink frequency1710-1755 MHz
Downlink frequency2110-2155 MHz
TX / RX modes4T4R
RF output power4 × 30 W/2 × 60 W
Interfaces / connectors4 × 7/16 ANT; 3 × SFP OPT; 1 × 3-screw terminal DC IN; 2 × QMA RX; 1 × 8-circular contact RET; 1 × D-sub MDR14 EAC; 1 × 2 × 15-contact LMP
Interfaces and data rates3 × SFP, 6 Gbit/s; 1 × RET; 1 × EAC; 1 × LMP
Power supplyNominal supply voltage: -48.0 V DC; Nominal input voltage range: -40.5 V DC to -57.0 V DC; Extended input voltage range: -36.0 V DC to -40.5 V DC -57.0 V DC to -60.0 V DC
FamilyFlexi
Installation environmentpole/wall installation; directly on the wall installation
IP ratingIP65
Additional technical information
Weight
23.7 kg (52.5 Ib)
Dimensions
Height: 459.5 mm (18.1 in.); Width: 400 mm (15.7 in.); Depth: 2 × 60 W version: 133.4 mm (5.2 in.) 4 × 30 W version: 162.3 mm (6.4 in.)
Bandwidth
DL instantaneous bandwidth: 45 MHz; UL instantaneous bandwidth: 45 MHz; DL filter bandwidth: 45 MHz; UL filter bandwidth: 45 MHz
Capacity
5G: up to 4 carriers per path (for 5G SA — after update via SRAN up to SRAN20A or later)
Synchronization
Synchronization from system module via OBSAI
Chassis
Remote radio unit housing Flexi RRH
Modules
Integrated: RF control; 4 transmit paths with PA; 4 receive paths with LNA; TX/RX-filters; PSU
Functional role
Remote base station radio unit
Architecture
Remote radio unit (Remote Radio Head)
Subtype
Flexi Remote Radio Head 4TX 1700/2100
Details
Minimum operating temperature, including cold start: −40 °C; maximum external: +55 °C in the shade, +50 °C in sunlight; indoor without fan: +45 °C. Output power may be limited during sustained high temperatures.
Installation conditions
Mast; wall
Connection notes
Power supply; antenna system; RET antennas; baseband unit via optical fibre

Related equipment

Compare models 0
Quote list 0

Review the model, part number and quantity for each position.