Nokia radio category illustration
Illustration
Nokia

FRAA

What it does: Converts and amplifies radio signals. Operating RF bands / ranges: 450 MHz.

1 part number: 473220A

Viewing: model overview

Request a Quote

Request current availability, condition and pricing. Delivery terms are agreed in the quotation.

Main specifications

TechnologiesFDD-LTE
Operating RF bands / ranges450 MHz
Uplink frequency452.5-457.5 MHz
Downlink frequency462.5-467.5 MHz
TX / RX modes2T2R
RF output power2 × 40 W
Interfaces / connectors2 × 4.3-10 ANT; 2 × SFP OPT; 1 × 3-screw terminal DC IN; 2 × QMA RX; 1 × 8-circular contact RET; 1 × D-sub MDR14 EAC; grounding: M8 or 2 × M5
Interfaces and data rates2 × SFP, 6 Gbit/s, OBSAI; 1 × RET; 1 × EAC
Power supplyInput DC: −40.5…−57 V; extended sections −36…−40.5 V and −57…−60 V
FamilyFlexi
Installation environmentpole/wall installation; directly on the wall installation; vertical book mount
IP ratingIP65
Additional technical information
Dimensions
Height: Core RRH: 371 mm (14.6 in) With upper and lower mounting brackets: 721 mm (28.4 in); Width: Core RRH: 291 mm (11.5 in) With plastic cover and mounting brackets: 302 mm (11.9 in); Depth: Core RRH depth without plastic cover: 169 mm (6.6 in) With plastic cover and mounting brackets: 215 mm (8.5 in)
Weight
Core RRH: 14.5 kg (32.0 lb) With plastic cover and mounting brackets: 16.2 kg (35.7 lb)
Bandwidth
DL instantaneous bandwidth: 5 MHz; UL instantaneous bandwidth: 5 MHz; DL filter bandwidth: 5 MHz; UL filter bandwidth: 5 MHz
Capacity
1 sector, 2TX MIMO; single-carrier LTE-mode with channel 3 or 5 MHz
Synchronization
Synchronization from system module via OBSAI
Chassis
Remote radio unit housing Flexi RRH
Modules
Integrated: RF control; 2 transmit paths with PA; 2 receive paths with LNA; TX/RX-filters; PSU
Functional role
Remote base station radio unit
Architecture
Remote radio unit (Remote Radio Head)
Subtype
Flexi RRH 2-pipe 450 80 W
Details
Minimum operating temperature, including cold start: −40 °C; maximum external: +55 °C in the shade, +50 °C in sunlight and wind 3 m/with; indoor without fan: +45 °C at air speed 0 m/with. Output power may be limited during sustained high temperatures.
Installation conditions
Mast; wall
Connection notes
Power supply; antenna system; RET antennas; baseband unit via optical fibre

Related equipment

Compare models 0
Quote list 0

Review the model, part number and quantity for each position.