Home/ Equipment/ Nokia/ AMOB AirScale Outdoor Subrack 473952A

AMOB AirScale Outdoor Subrack

473952A

Nokia Modules, Boards, Subracks & Enclosures Data status recorded
Technical product identity

Nokia AMOB AirScale Outdoor Subrack 473952A

Nokia AMOB AirScale Outdoor Subrack 473952A. Outdoor Subrack / Enclosure for the AirScale Outdoor Subracks & Enclosures. Function: Standalone outdoor protective cabinet/subrack/enclosure intended to house system modules and provide environmental protection. Compatible host/equipment: Compatible BBU/Baseband: Designed to house Nokia AirScale or Flexi system/common/capacity units according to the enclosure type. Compatible RRU/RRH/AAU: Remote radios remain externally mounted and connect by CPRI/eCPRI fiber and -48 V DC. System modules: PDU, fan units, heaters, common/capacity modules, alarm and grounding components as defined by cabinet BOM. Cabinets/subracks: This item is itself the cabinet/subrack; compatible plinth, anchoring and cable-entry accessories are required. Antennas/AAU: External antenna/radio system depends on installed network configuration. Required companion equipment: PDU, common units, capacity units, fan units, heaters where specified, alarm interface, grounding bar and cable-entry/gland set. Slot/form factor: 8U. Interfaces: Backplane for up to 2 common and 6 capacity plug-in units; fan/heater/PDU interfaces; O&M through installed common unit. Power: -48 V DC through integrated PDU / common-unit power feeds. Installation: Floor/plinth or site-frame mounting. Verification status: Model/item-level where cited; Outdoor enclosure confirmed; civil fasteners depend on foundation and site standard.

Manufacturer
Nokia
Model
AMOB AirScale Outdoor Subrack
Part Number
473952A
Equipment Type
Modules, Boards, Subracks & Enclosures
Host Platform
AirScale Outdoor Subracks & Enclosures
Primary Function
Standalone outdoor protective cabinet/subrack/enclosure intended to house system modules and provide environmental protection.
Slot / Form Factor
8U
Compatible Host
Compatible BBU/Baseband: Designed to house Nokia AirScale or Flexi system/common/capacity units according to the enclosure type. Compatible RRU/RRH/AAU: Remote radios remain externally mounted and…
Last Verified
July 2026

Module / Infrastructure Function

Main CategoryCabinets, Racks & Enclosures
Equipment SubtypeOutdoor Subrack / Enclosure
Platform / Host SystemAirScale Outdoor Subracks & Enclosures
Primary FunctionStandalone outdoor protective cabinet/subrack/enclosure intended to house system modules and provide environmental protection.

Host & Equipment Compatibility

Compatible Host / EquipmentCompatible BBU/Baseband: Designed to house Nokia AirScale or Flexi system/common/capacity units according to the enclosure type. Compatible RRU/RRH/AAU: Remote radios remain externally mounted and connect by CPRI/eCPRI fiber and -48 V DC. System modules: PDU, fan units, heaters, common/capacity modules, alarm and grounding components as defined by cabinet BOM. Cabinets/subracks: This item is itself the cabinet/subrack; compatible plinth, anchoring and cable-entry accessories are required. Antennas/AAU: External antenna/radio system depends on installed network configuration.
Required Companion EquipmentPDU, common units, capacity units, fan units, heaters where specified, alarm interface, grounding bar and cable-entry/gland set.
Related Radios / BBURemote radios remain externally mounted and connect by CPRI/eCPRI fiber and -48 V DC
Compatible Cabinet / SubrackThis item is itself the cabinet/subrack; compatible plinth, anchoring and cable-entry accessories are required
Slot / Form Factor8U

Interfaces & Power

Interfaces & ConnectorsBackplane for up to 2 common and 6 capacity plug-in units; fan/heater/PDU interfaces; O&M through installed common unit
Transport / Optical InterfacesBackplane for up to 2 common and 6 capacity plug-in units; fan/heater/PDU interfaces; O&M through installed common unit
Power Source-48 V DC through integrated PDU / common-unit power feeds
Power Connector TypeExternal Anderson-type / high-current -48 V DC input to the PDU; internal power outputs to plug-in units
Required Power / Internal CableNokia AMOB power cable with matching high-current DC plug
Power ConsumptionConfiguration-dependent; fans and optional heaters are additional to installed baseband units

Installation & Thermal Role

Cooling / Thermal RoleIntegrated or optional fan/heater system; keep airflow path and IP sealing
Installation LocationOutdoor
Mounting MethodFloor/plinth or site-frame mounting
Mounting Kit / HardwareAMOB/AMOC/AMOD plinth/base, anchor set, fan/heater mounting hardware and cable-entry/gland set
Known Mounting Kit PNsExact plinth/anchor-kit PN not confirmed for each outdoor subrack
Fasteners / FixingsM10/M12 concrete or steel-frame anchors as required by site design; internal rack/captive screws for plug-in units; grounding/bonding hardware
Cables & ConnectionsMain -48 V DC feed; internal DC distribution harness; Ethernet and optical patch cords; grounding/bonding cable; fan/heater power; alarm cable; cable glands and strain-relief accessories
Dimensions355 × 487 × 605 mm (8U)
Weight23 kg empty / 42.2 kg fully equipped
Operating Temperature-40 to +55 °C outdoor; IP55 enclosure

Identity & Verification

Data / Compatibility StatusModel/item-level where cited; Outdoor enclosure confirmed; civil fasteners depend on foundation and site standard
Battery / ShippingNo internal battery specified; Normally ships without a battery; verify that no separate battery accessory is packed
Structured equipment graph

Compatible Equipment & Engineering Relationships

1 relationship rows

Each relation retains its evidence level. Family-level, platform-level and engineering-selection relations are not displayed as exact part-number compatibility.

Hosts equipment

ASIA AirScale Common; ASIB AirScale Common; ASIK AirScale Common; ASIKA AirScale Common; ABIA AirScale Baseband; ABIC AirScale Baseband; ABIL AirScale Baseband; ABIO AirScale Baseband; ABIP AirScale Baseband; ABIL; ABIQ Platform-level Required for enclosed configuration

Target part number(s): 473095A; 473764A; 474021A; 474424A; 474403A; 473096A; 474723A; 474020A; 475266A; 475792A; 474020B; 476397A

Interface / role: Mechanical, power and cooling enclosure

Conditions: Loaded mass, thermal load and PDU capacity must be checked

Referenced by Other Equipment

Worldwide telecom sourcing

Can’t find the exact model or configuration?