What it does: Converts and amplifies radio signals. Operating RF bands / ranges: GSM1900.
1 part number: KRC161028/4
Viewing: model overview
Request a QuoteRequest current availability, condition and pricing. Delivery terms are agreed in the quotation.
Main specifications
Operating RF bands / rangesGSM1900
Interfaces and data ratesElectrical Y-link to IXU-21; distance to 5 m for station expansion; RF-interfaces; DC-external fan power output
Installation environmentOn mounting base MBU; wall, support or mast; outdoor or indoor installation as part of RBS2109
Additional technical information
- Family
- PN KRC161028 / 4; RRU-H19 Edge
For PN KRC161028 / 4. - Power supply
- PN KRC161028/4; -48 V DC
For PN KRC161028/4. - Technologies
- PN KRC161028/4; GSM/EDGE: GMSK, 8PSK, 16QAM and 32QAM
For PN KRC161028/4. - Downlink frequency
- PN KRC161028/4; 1930.4–1989.6 MHz certified transmitter range
For PN KRC161028/4. - RF output power
- PN KRC161028/4; Maximum nominal RMS: 41.5 dBm GMSK; 38.2 dBm 8PSK; 36.8 dBm 16QAM; 36.4 dBm 32QAM
For PN KRC161028/4. - Capacity
- 2 GSM TRX per RRU-H
- Chassis
- Separate replaceable unit RRU-H, on mounting base hinges MBU station RBS2109
- Modules
- 2 integrated TRX; integrated heater; external plug-in options RXBP and fan
- Functional role
- PN KRC161028/4; GSM base-station remote radio unit
For PN KRC161028/4. - Architecture
- Diversity IXU-21 and RRU-H, electrical Y-link; 1–3 RRU-H per IXU-21
- Subtype
- PN KRC161028/4; Remote radio unit
For PN KRC161028/4. - Details
- Encryption A5/1 or A5/2 with software selection; heater active only during AC-power supply, warm-up to 75 min