Home/ Equipment/ Nokia/ FPFD Power Distribution Module 472301A

FPFD Power Distribution Module

472301A

Nokia Modules, Boards, Subracks & Enclosures Platform-level data
Technical product identity

Nokia FPFD Power Distribution Module 472301A

Nokia FPFD Power Distribution Module 472301A. Power Module for the Flexi System Modules. Function: Plug-in module, board, common/capacity unit, support unit or subrack component. Compatible host/equipment: Compatible BBU/Baseband: Flexi system module or AirScale baseband platform matching the module generation. Compatible RRU/RRH/AAU: Nokia Flexi or AirScale radios subject to platform/release compatibility. System modules: Required host subrack/backplane, common/control unit, capacity and power modules. Cabinets/subracks: Flexi FMFA/FCOB or AirScale AMIA/AMOB/AMOC/AMOD as applicable. Antennas/AAU: Determined by connected radio. Required companion equipment: Compatible Flexi/AirScale host, processing/common unit, transport, capacity, fan and power modules according to the platform BOM. Slot/form factor: 19-inch or vendor-specific form factor; verify exact chassis. Interfaces: RF: No RF connectors; Fronthaul/transport: no optical fronthaul ports; Power: -48 V DC input/output via power terminals or vendor-specific connectors; Management/synchronization: alarm/monitoring through the backplane or service harness; Other: backplane and power contacts. Power: -48 V DC input/output distribution. Installation: Plug-in slot, backplane or internal rack position. Verification status: Mixed / revision check; Board/module installation confirmed at host-platform level.

Manufacturer
Nokia
Model
FPFD Power Distribution Module
Part Number
472301A
Equipment Type
Modules, Boards, Subracks & Enclosures
Host Platform
Flexi System Modules
Primary Function
Plug-in module, board, common/capacity unit, support unit or subrack component.
Slot / Form Factor
19-inch or vendor-specific form factor; verify exact chassis
Compatible Host
Compatible BBU/Baseband: Flexi system module or AirScale baseband platform matching the module generation. Compatible RRU/RRH/AAU: Nokia Flexi or AirScale radios subject to platform/release compatibility.…
Last Verified
July 2026

Module / Infrastructure Function

Main CategorySystem Modules, Boards & Subracks
Equipment SubtypePower Module
Platform / Host SystemFlexi System Modules
Primary FunctionPlug-in module, board, common/capacity unit, support unit or subrack component.

Host & Equipment Compatibility

Compatible Host / EquipmentCompatible BBU/Baseband: Flexi system module or AirScale baseband platform matching the module generation. Compatible RRU/RRH/AAU: Nokia Flexi or AirScale radios subject to platform/release compatibility. System modules: Required host subrack/backplane, common/control unit, capacity and power modules. Cabinets/subracks: Flexi FMFA/FCOB or AirScale AMIA/AMOB/AMOC/AMOD as applicable. Antennas/AAU: Determined by connected radio.
Required Companion EquipmentCompatible Flexi/AirScale host, processing/common unit, transport, capacity, fan and power modules according to the platform BOM.
Related Radios / BBUNokia Flexi or AirScale radios subject to platform/release compatibility
Compatible Cabinet / SubrackFlexi FMFA/FCOB or AirScale AMIA/AMOB/AMOC/AMOD as applicable
Slot / Form Factor19-inch or vendor-specific form factor; verify exact chassis

Interfaces & Power

Interfaces & ConnectorsRF: No RF connectors; Fronthaul/transport: no optical fronthaul ports; Power: -48 V DC input/output via power terminals or vendor-specific connectors; Management/synchronization: alarm/monitoring through the backplane or service harness; Other: backplane and power contacts
Transport / Optical InterfacesNo optical fronthaul ports
Power Source-48 V DC input/output distribution
Power Connector TypeTerminal or vendor-specific -48 V DC distribution connector; exact implementation depends on the power-module revision
Required Power / Internal Cable-48 V DC power cable with a mating Nokia plug, terminals or cable harness
Power ConsumptionEstimated maximum 250 W

Installation & Thermal Role

Cooling / Thermal RoleHost-chassis airflow; observe current and thermal derating
Installation LocationInside host chassis/subrack
Mounting MethodPlug-in slot, backplane or internal rack position
Mounting Kit / HardwareNo separate external mounting kit; use host chassis guide rails, ejector handles, captive screws and filler panels
Known Mounting Kit PNsNo standalone mounting-kit PN; host chassis hardware applies
Fasteners / FixingsCaptive faceplate screws, board ejector handles, guide rails and slot filler panels. Do not improvise external mounting.
Cables & ConnectionsHost backplane connection; optical/Ethernet patch cord where the module exposes front ports; internal power through backplane; alarm/synchronization cable only when the specific module provides that interface
Dimensions133 × 447 × 300 mm
Weight6.0 kg net
Operating Temperature-5 to +55 °C

Identity & Verification

Data / Compatibility StatusMixed / revision check; Board/module installation confirmed at host-platform level
Battery / ShippingNo battery installed in the listed power module; The listed module normally ships without a battery. A separately supplied FPBA/FPBB must be handled and declared as lithium-battery equipment
Structured equipment graph

Compatible Equipment & Engineering Relationships

1 relationship rows

Each relation retains its evidence level. Family-level, platform-level and engineering-selection relations are not displayed as exact part-number compatibility.

Requires Flexi host/baseband

Referenced by Other Equipment

Worldwide telecom sourcing

Can’t find the exact model or configuration?