Target part number(s): 02311VFF
Interface / role: Hosts control and baseband boards
Conditions: Board generation, CPRI/eCPRI port, RAT and software must match
02313LFF
Huawei RRU5916e B1 02313LFF. Remote radio unit for B1 (2100 MHz); 2T2R or 4T4R depending on variant; output Estimated 160–240 W total. Compatible baseband: Huawei BBU5900 with compatible UMPT control/transmission board and UBBP baseband board; legacy BBU3900/3910 may support selected RRU3000 variants. Required modules and boards: UMPT control/transmission board; UBBP baseband board with sufficient CPRI/eCPRI ports; UPEU/UPBA power and support; DCDU distribution; synchronization/GNSS/PTP; optical modules. Fronthaul: SFP/SFP+ optical CPRI; newer variants may support eCPRI. RF interface: 4.3-10 female (typical for RRU5000). Power: -48 V DC; typical input range -36 to -57 V DC. Mounting: Standard pole 60–114 mm, wall or special/large pole 114–400 mm; multi-RRU pole arrangements supported by model. Verification status: Family-level; Official installation method and fastener sizes confirmed; exact mounting-kit PN is model/BOM-dependent.
| Band | B1 |
|---|---|
| Frequency | 2100 MHz |
| TX / RX Configuration | 2T2R or 4T4R depending on variant |
| Output Power | Estimated 160–240 W total |
| Supported Standards | LTE/LTE-A, NB-IoT and 5G NR; exact RAT support depends on band and software |
| Compatible BBU / Baseband | Huawei BBU5900 with compatible UMPT control/transmission board and UBBP baseband board; legacy BBU3900/3910 may support selected RRU3000 variants |
|---|---|
| Required Modules & Boards | UMPT control/transmission board; UBBP baseband board with sufficient CPRI/eCPRI ports; UPEU/UPBA power and support; DCDU distribution; synchronization/GNSS/PTP; optical modules. |
| Compatible Cabinets / Subracks | Huawei outdoor cabinet or pole/wall installation with external -48 V DC distribution |
| Compatible Passive Antenna | Passive band-matched antenna with RF jumpers and AISG/RET control |
| RF Connector Type | 4.3-10 female (typical for RRU5000) |
|---|---|
| Fronthaul Interface | SFP/SFP+ optical CPRI; newer variants may support eCPRI |
| Optical Form Factor | SFP+ / SFP28 |
| Optical Speed | CPRI / eCPRI, typically 10 or 25 Gbit/s |
| Optical Connector | LC duplex |
| Optical Reach | Typical 300 m MMF or 10–20 km SMF |
| Known Optical Part Numbers | Huawei-approved optical module matched to UBBP/UMPT interface and software release. |
| AISG / RET / Control | AISG/RET; maintenance/alarm |
| Power Supply | -48 V DC; typical input range -36 to -57 V DC |
|---|---|
| Power Connector Type | 2-pole tool-less / quick-fit -48 V DC connector (NEG-/RTN+); exact implementation depends on the RRU5000 revision |
| Required DC Power Cable | Huawei shielded two-core RU power cable with the vendor-specific press-fit / quick-fit plug |
| Power Consumption | Estimated maximum 550 W |
| Installation Environment | Outdoor |
| Mounting Method | Standard pole 60–114 mm, wall or special/large pole 114–400 mm; multi-RRU pole arrangements supported by model |
| Mounting Kit / Hardware | Main mounting bracket plus auxiliary/pole bracket. Standard pole uses square-neck bolt assemblies; wall uses main bracket and expansion bolts; large pole uses steel strips and clamp brackets. |
| Known Mounting Kit PNs | Standard Huawei RRU mounting kit supplied/selected by model; exact kit PN not confirmed in public guide |
| Fasteners / Fixings | Standard pole: dual-nut square-neck bolt assemblies. Wall: M8 expansion bolts for common eRRU variants; RRU3232b/RRU5251-style wall bracket uses M10 nuts/anchors. Large pole: steel straps and M6×16 bolts. Typical torques: 5 N·m for captive/M6 bracket screws, 15–30 N·m for anchors/clamps as specified. |
| Cooling | Passive heat-sink cooling |
| Cables & Connections | CPRI/eCPRI optical fiber cable; -48 V DC two-core power cable; protective grounding cable; RF jumpers from radio to passive antenna; AISG/RET cable when external antenna control is used; weatherproofing/sealing kit; shielded RU power cable with press-fit/quick-fit connector and NEG(-)/RTN(+) polarity |
| Dimensions | 400 × 300 × 100 mm |
| Weight | 14 kg net |
| Operating Temperature | -40 to +55 °C |
| Data / Compatibility Status | Family-level; Official installation method and fastener sizes confirmed; exact mounting-kit PN is model/BOM-dependent |
|---|---|
| Region | Europe; Asia-Pacific; Middle East; Africa; Latin America |
| Representative Countries | United Kingdom, Germany, France, Italy, Spain, Netherlands, Poland, Sweden, Finland, Turkey, Saudi Arabia, United Arab Emirates, Egypt, South Africa, China, Japan, South Korea, India, Thailand, Malaysia, Indonesia, Australia, New Zealand, Brazil, Chile |
| Battery / Shipping | No internal battery specified; Normally ships without a battery. Any separately packed DBU lithium battery is a distinct regulated item |
Frequency compatibility is shown separately from documented deployment or regulatory approval.
Each relation retains its evidence level. Family-level, platform-level and engineering-selection relations are not displayed as exact part-number compatibility.
Target part number(s): 02311VFF
Interface / role: Hosts control and baseband boards
Conditions: Board generation, CPRI/eCPRI port, RAT and software must match
Target part number(s): Standard Huawei RRU mounting kit supplied/selected by model; exact kit PN not confirmed in public guide
Interface / role: Mechanical installation
Conditions: Official installation method and fastener sizes confirmed; exact mounting-kit PN is model/BOM-dependent
Target part number(s): Huawei-approved optical module matched to UBBP/UMPT interface and software release.
Interface / role: CPRI / eCPRI, typically 10 or 25 Gbit/s
Conditions: Optical rate, wavelength, fiber type and budget must match both ends
Target part number(s): 03022HEG; 03022HEH; 03022HEJ; 03022HEK; 03022HEL; 03022HEM; 03022NJR; 03057152; 03057153; 03057154; 03057155; 03057157; 03057158; 03059443; 03058626; 03020HKJ; 03020KXC; 03020LAJ; 03020KWP; 03020GSA; 03020SSA; 03020QYR; 03020XCN; 03020QYB; 03020UAQ
Interface / role: Baseband processing and CPRI/eCPRI ports
Conditions: Board capacity and radio interface must match
Target part number(s): 03053947; 03054885; 03054886; 03057389; 03055702; 03057251; 03057252; 03057264; 03058541; 03058543
Interface / role: Control, transport and synchronization
Conditions: Select a UMPT supported by the BBU and software release
Target part number(s): External antenna PN selected by band, port count and gain
Interface / role: RF radiation and reception
Conditions: Match band, polarization, port count, connector and PIM rating
Send the manufacturer, model, part number, quantity and destination country. Requests may include equipment not yet listed in the catalog.