Ericsson
AIR 6449 B79A
What it does: Transmits and receives radio signals. Operating RF bands / ranges: B79A.
1 part number: KRD901120/11
Viewing: model overview
Request a QuoteRequest current availability, condition and pricing. Delivery terms are agreed in the quotation.
Main specifications
Technologies5G NR TDD
Operating RF bands / rangesB79A
Uplink frequency4800–5000 MHz
Downlink frequency4800–5000 MHz
TX / RX modes64T64R branches
RF output power320 W maximum nominal; HWAC required above 20 W
Interfaces / connectorsSMA female TX-monitor; 4 × LC optical connectors on SFP/SFP28 with FullAXS; DIN-14 female; −48 V DC power connector; 2 × 6 mm grounding lug
Interfaces and data rates4 × optical eCPRI up to 25.8 Gbps to Baseband; DIN-14 supports RAE, EC-light and external alarms; grounding and DC power
Power supply−48 V DC rated (−36.0 to −58.5 V operating); recommended circuit breaker 40 A at 100% RF output; maximum allowed 50 A
FamilyAIR 6449
Installation environmentOutdoor wall, pole, tower or mast mounting
IP ratingIP65 (IEC 60529 / EN 60529)
Additional technical information
- Dimensions
- 728 × 485 × 218 mm (H × W × D)
- Weight
- 40.1 kg (±5%)
- Bandwidth
- B79A: instantaneous bandwidth 200 MHz; operational bandwidth 200 MHz
- Capacity
- Maximum MIMO capability: 16 downlink layers; 8 uplink layers
- Synchronization
- Traffic and timing signals carried between AIR 6449 and Baseband through the optical eCPRI interfaces
- Chassis
- Self-contained outdoor AIR enclosure with radome, covers and heat-sink
- Modules
- Up to 4 Ericsson-approved SFP/SFP28 optical transceiver modules for eCPRI data ports
- Functional role
- Outdoor antenna-integrated mid-band radio unit connecting an active antenna array to Baseband over eCPRI
- Architecture
- Warranty-sealed integrated active-antenna radio with up to 64TX/64RX branches, passive convection cooling and four optical eCPRI links
- Subtype
- 64TX/64RX Massive-MIMO active antenna system for NR TDD
- Details
- Passive convection cooling with no active cooling; −40 to +55 °C; 2–100% relative humidity; output power may temporarily reduce in the highest 10 °C depending on installation, load and configuration